Garbage collection on Solidfire starts at the top of every hour: To run the job manually https://{mgmt-vip}/json-rpc/5.0?method=StartGC If you need to run a check on the status of the GC then you can use the following command https://{mgmt-vip}/json-rpc/5.0?method=GetGCStatus
Category: NetApp
Increase iNodes on Netapp FAS
Problem Our alerting system notified us that inodes were nearing the system limit on a CIFS share (aka unipod_cifs) on a FAS running ONTap 9 Solution The following command will shiow current usage syntax volume show {cifs_name} -fields files, files-used command volume show unipod_cifs -fields files, files-used To increase the inodes use the following syntax Read More…
Convert NetApp Ports from FC to CNA
Problem I wanted to convert two FC ports to CNA (10Gb eth) mode on a Netapp AFF-300. The ports in question are 0e and 0f. Steps The following will work for FAS units as well. Display internfaces: sannapp02::> ucadmin show Current Current Pending Pending Read More…
New Node Gets Stuck in PendingActive State – NetApp Solidfire
Problem: When trying to add a new NetApp Solidfire (H610S4) node to an existing cluster the node became locked in a PendingActive state. Troubleshooting The log files showed the following error: 2019-11-25T13:47:50.149221Z node-sans11 master-1[26688]: [Bootstrapper] 26749 TickerIOService ms/Bootstrapper.cpp:1648:RunClusterSearch|Error in cluster search: ex=xInvalidVirtualNetwork at solidfire::IPAddress solidfire::VirtualNetworkInfo::ReserveAddress() (shared/VirtualNetworkInfo.cpp:302): Too few IP addresses supplied for VirtualNetwork 8 Read More…