Transfer Spooling Area is not Writable in vCloud Director

Issue: During a new install of vCloud Director 8.20 on Centos 6.9 the service failed to start properly for the first time.      Troubleshooting: I investigated log files # tail -f /opt/vmware/vcloud-director/logs/cell.log Output: Application Initialization: 'com.vmware.vcloud.common.core' 100% complete. Subsystem 'com.vmware.vcloud.ui-vcloud-webapp' started Application Initialization: 'com.vmware.vcloud.common.core' complete. Server is ready in 1:05 (minutes:seconds) Successfully handled all Read More…

Upgrade NSX 6.2.4 to 6.3.4 in a vCloud Environment

This document describes how to upgrade NSX in a VCD environment. We will be upgrading NSX from 6.2.4 -> 6.3.4 Current Components Component Version vCloud Director 8.20.0 ESXi 5.5 U3 vCenter 5.5 U3 NSX 6.2.4 Chargeback Manager 2.7.3   Check Interoperability Matrices   Pre-installation Take a clone of  NSX Manager  Take backup of NSX manager Read More…

SSL VPN-Plus Client Fails to Connect

After upgrading from vShield Edge 5.5.4 -> NSX Edge 6.2.4 -> then converting to Advanced Gateway in a vCloud Director (8.20) environment all of my SSL VPN connections failed to establish. The following appeared:   "Error: Connection to gateway failed. Please contact your administrator for SSL VPN-Plus gateway settings."   Looking at the version it appeared I Read More…

VCNS 5.5 – Upgrade Failed. Root Fileystem Full

When trying to upgrade VCNS 5.5.3 to 5.5.4 I was presented with this error: Message: Could not untar /common/em/downloads/image/image-vsm-vsm-5.5.4-2504419.img.dist   This suggested to me there was a partition full somwhere on the vShield Manager VM To check this: Open the console of the VSM VM. Default username/passwords are:  Username: admin Passowrd: default Enable: default #' show Read More…